Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177573 W

PWXEDM
177573
W

Inconsistent definitions for
full_table_name


- or -
Inconsistent definitions for table
Creator: creator_name
Table: table_name
- or -
Inconsistent definitions for table
Creator: creator_name_ ....
continued_creator_name
Table: table_name_ ....
continued_table_name

The DB2 ECCR attempted to obtain a description of the specified table from the in the DDB2 ECCR capture directory TCAPTABLES table, but the obtained description was inconsistent. Probably, DDL activity is updating the catalog descriptions concurrently with the DB2 ECCR access.
The DB2 ECCR issues the modified formats of the message in the following cases:
  • If the fully-qualified table name is in excess of 70 characters long
  • If either the creator name or table name are longer than 80 characters
    Each part of the fully-qualified table name is on a separate line in the message.
The DB2 ECCR abends.
Collect the complete DB2 ECCR job listing, including the SYSUDUMP output. Then, contact Informatica Global Customer Support.