EDM Logger unable to process log truncation request for reason
reason
The PowerExchange Logger off‑load processor encountered an error while attempting to truncate the current active log. While processing an ARCHIVE_LOG command, the PowerExchange Logger physical logger routine received an internal request to force‑write the log buffer and to truncate and switch the active log to the next available active log data set.
This is an internal error detected by the PowerExchange physical logger. The error may have been caused by an unrelated abend in the PowerExchange physical logger, a STOP MODE=FORCE command, or an abnormal subsystem termination.
As indicated by reason code
reason
, the request failed for one of the following reasons:
04. The end of current active log operation failed.
08. The determine new active log operation failed.
The PowerExchange Logger stops processing the command.
Look up the messages and abends that precede this message for possible causes of the error. If possible, correct the problem and run the job again. If the problem persists, collect all available information about the error and contact Informatica Global Customer Support.