The PowerExchange Logger for MVS failed to process a RESOLVE_INDOUBT COMMIT or ABORT command. The message reports one of the following error types:
UOW not found
. The PowerExchange Logger did not find the specified UOW.
ECCR=
eccr_name
. The PowerExchange Logger found the specified UOW, but the name of the ECCR that is associated with the UOW is incorrect.
Gbl Queue error
. An error occurred while PowerExchange was attempting to write a command notification to the PowerExchange Logger input queue.
Pkt Queue error
. The UOW information could not be added to the PowerExchange Logger internal queue.
EDMLLLG0 error
. An error occurred while the EDMLLG0 module was processing the command.
The RESOLVE_INDOUBT command fails, but PowerExchange Logger processing continues.
If the UOW was not found, verify that the UOW ID specified in the RESOLVE_INDOUBT command matches the UOW ID shown in the DISPLAY OBJ=CONN,TYPE=UOW command output. If the ECCR name was incorrect, verify that the correct ECCR name is specified in the RESOLVE_INDOUBT command. After you correct either error, run the RESOLVE_INDOUBT UOW command again. If the problem persists, contact Informatica Global Customer Support.
If another error type caused the failure, contact Informatica Global Customer Support.