Message Reference Volume 3

PWXEDM 172777 E

PWXEDM
172777
E

EDM Logger received
record_type
record with no Begin_UOW from ECCR
eccr_name
for UOW
uowID
, SEQ=
seq_no
PowerExchange issues this error message each time it encounters a record from an ECCR where the ECCR had not provided the corresponding begin UOW record.
Record_type
indicates the type of record and can have one of the following values:
  • BEGIN_PH1. begin‑phase‑1 record.
  • BEGIN_PH2. begin‑phase‑2 record.
  • END_PH2. end‑phase‑2 record.
  • CHANGE. change record.
    eccr_name
    indicates the name of the ECCR.
    uowID
    indicates the UOW ID of the UOW that was assigned by the ECCR.
    seq_no
    indicates the ECCR‑assigned sequence number for the record.
    This message is issued as a WTO, and the message also appears in the EDMSLOG file of the PowerExchange Agent.
Check the JES2 log for previous messages from the PowerExchange Logger. Also examine the ECCR that provided the data for any previous messages. If you cannot determine the problem from previous messages, contact Informatica Global Customer Support and have the job step listings available.