PWXEDM 177613E

PWXEDM
177613
E

DB2 READS LOGICAL FAILURE, LOG RECORDS(S) RETURNED {BEYOND END-OF-SCOPE|BEFORE READ POINT|BEFORE LAST RETURNED}
The DB2 ECCR encountered out-of-sequence log records. The message indicates why the ECCR determined the records were out of sequence. Messages PWXEDM177611I and PWXEDM177612I, which immediately precede this one, provide more information about the error.
The DB2 ECCR abends.
Contact Informatica Global Customer Support. Provide Support with the complete DB2 ECCR job listing, including SYSUDUMP output.