Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172831 I

PWXEDM
172831
I

Capture Status {not resolved|resolved as inactive} for
structure_name
, DEST=SUBSYS
This message is issued by the CIC component of IMS online capture when either a repository call to determine capture status failed or when resolution of capture status occurs after a repository call failure.
If the capture status is undetermined and CCERR=ABEND is specified in the EDMSDIR parameters, transactions that attempt to UPDATE the database will ABEND with a U4094.
Determine why the repository call failed by checking the PowerExchange Agent status and the PowerExchange Agent message log (EDMSLOG). Take the necessary action to correct the problem. The status of all undetermined databases is resolved when the next database OPEN initiates a repository call. If the cause of the error cannot be determined, contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!