Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172667 E

PWXEDM
172667
E

EDM Logger Reader
operation
failed for
lrp_client
with reason code
reason
, and return code
rc
The specified PowerExchange Logger reader operation
operation
failed for LRP client
lrp_client
. The reason code
reason
and the return code
rc
provide additional information about the error.
The variable
operation
indicates which operation was running and is one of the following:
  • BLDPIP. A build SENDPIPE command failed.
  • BLDRDT. An attempt to build a request data transfer (REQTRN) reply command failed.
  • CLOSE. An attempt to close a circular queue failed.
  • CSCONN. A common services CONNECT failed.
  • INVRBA. The PowerExchange Logger reader was unable to find a valid log data set, or it found a log data set with an invalid RBA.
  • OPEN. An attempt to open an output circular queue failed.
  • OPNXCF. An attempt to open a XCF message queue failed.
  • PUT. An attempt to PUT to a circular queue failed.
  • RDINIT. The logical log reader was unable to initialize.
  • RDTERM. An attempt to terminate processing by the logical log reader failed.
  • RDTRPL. An attempt to send a request data transfer command (REQTRN) reply through the circular queue failed.
  • READ. An attempt by the logical log reader to READ from a log failed.
  • REREAD. An attempt by the logical log reader to READ from a log failed.
  • SNDPIP. An attempt to insert a pipe cleaner in a circular queue failed.
  • SNDRDT. An attempt to send a request data transfer (REQTRN) reply command failed.
  • TERM. A logical log reader failed to terminate.
  • UNALLO. An attempt to have the logical log reader unallocate the current log data set failed.
  • UOWFND. The exact position in the log data from which data transfer is supposed to start cannot be found.
The PowerExchange Logger stops abnormally.
To determine the cause of the problem, look at the values of
operation, reason
, and
rc
.
Correct the problem, restart the PowerExchange Logger, and run the job again. If the problem persists, collect all available information about the error, including the contents of this message, and contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!