Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 176431 I

PWXEDM
176431
I

Syncpoint processing entered,
area
value is
contents
The PowerExchange task-related user exit (TRUE) was invoked during syncpoint processing. The exit dumps the first 64 bytes of the contents of the CICS parameter area, TRWA data area, or TFWA control block to this message for diagnostic use.
In this message,
area
is one of the following values:
  • FUNC
  • TFWA control block
  • TRWA data area
CICS processsing continues.
Send the contents of this message to Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!