Message Reference Volume 3

PWXEDM 176451I

PWXEDM
176451
I

Change Capture disallowed for File(
file_id
) due to CAPTURE_
vsam_source_type
=OFF CDC Override Option
PowerExchange will not capture change data for the specified VSAM file because change data capture is disabled for all VSAM files of that type by the
CAPTURE_
VSAM_source_type
=OFF
statement in the override options data set.
You can disable change data capture for a VSAM source type by setting any of the following options to OFF: CAPTURE_ESDS, CAPTURE_KSDS, CAPTURE_RRDS, or CAPTURE_CMDT.
For the CAPTURE_ESDS option, the default value is OFF.
No response is required.