The format utility (EDMLUTL0) for the PowerExchange Logger active log data sets has abended due to an error that occurred while formatting the data set. The routine in which the error occurred, and the hexadecimal value of the return code and reason code for the operation that failed, are included in the text of the message. The value for the routine could be one of the following:
GETM-PGE GETMAIN
GENCB GENCB (ACB)
SHOW-OPN SHOWCB FIELDS=(ERROR)
OPEN OPEN (ACB)
SHOWCB SHOWCB FIELDS=(XENDRBA,XHALCRBA)
SHOW-CLO SHOWCB FIELDS=(ERROR)
CLOSE CLOSE (ACB)
DSPSERV DSPSERV CREATE
DIV-IDNT DIV IDENTIFY
DIV-ACC DIV ACCESS
DIV-MAP DIV MAP
HSPSERV HSPSERV SWRITE
DIV-SAV DIV SAVE
The utility is terminated.
Determine the cause of the failure from the return code and reason code that were issued for the failing operation, by consulting the appropriate IBM product documentation. If the problem cannot be identified, collect the output from the failing job, and contact Informatica Global Customer Support.