Message Reference Volume 3

PWXEDM 172633 E

PWXEDM
172633
E

EDM Logger restart data set with
ddname
ERDS02 is empty
The PowerExchange Logger requires at least one restart data set to operate. The data set allocated to ERDS02 is empty. Processing continues with only one restart data set.
Check the PowerExchange Logger restart data sets in the JCL to verify that the correct second data set was specified and that it exists.