The internal state of the DB2 ECCR capture directory tables is not correct.
This message is usually issued during an ECCR special start, when a DDL operation that deletes a tablespace occurs between the time the log record that is used for the special start is written and the time the special start is executed.
The DB2 ECCR abends.
Ensure that only the DB2 ECCR or capture directory utility updates the capture directory tables.
If you performed a special start, either try performing a cold start or retry the special start immediately after the point in the log where the error occurred. If this issue did not occur during a special start, or if you performed a special start and processed the DB2 log up to the current point in time, gather all ECCR job output, including the dump output, and then contact Informatica Global Customer Support.