The DB2 ECCR could not find a row in one of the following DB2 catalog tables:
SYSTABLESPACE
SYSCOLUMNS
SYSFIELDS
This issue can occur during ECCR warm start or refresh processing in the following situations:
A new capture registration is being processed for a table that was dropped or that was altered in a way that is inconsistent with the capture registration prior to the warm start or refresh command.
DDL activity is occurring against the table or its table space.
The DB2 ECCR abends.
For the first situation, verify that the capture registration for the table matches the current table definition. If the table was dropped, delete the capture registration and warm start the DB2 ECCR. For the second situation, try to warm start the ECCR. If the ECCR fails again, complete the recommended actions for the first situation.