Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177543 E

PWXEDM
177543
E

Capture program of DB2 Replication ending - DB2 Catalog tables not Data Capture Changes
During initialization, the DB2 ECCR determined that one or more of the DB2 catalog tables that it uses does not have the required DATA CAPTURE CHANGES attribute. The ECCR uses the following catalog tables:
  • SYSIBM.SYSTABLES
  • SYSIBM.SYSCOLUMNS
  • SYSIBM.SYSTABLESPACE
  • SYSIBM.SYSFIELDS
  • SYSIBM.SYSCOPY.
Message PWXEDM177398E indicates which of these tables are missing the attribute.
The DB2 ECCR ends without processing any DB2 log data.
Set the DATA CAPTURE CHANGES attribute on the catalog tables that are missing the attribute. Then cold start or special start the ECCR. If you warm start the ECCR, it does not recognize the current status of the DB2 catalog tables and fails, even if the DB2 catalog tables were altered to add the DATA CAPTURE CHANGES attribute.

0 COMMENTS

We’d like to hear from you!