PWXEDM 175016 I

PWXEDM
175016
I

message_text
, return code=
rc
, reason=
reason
, logrba=
logrba
The PowerExchange Create Event Marker utility issues this message to indicate the status of an event command.
The message text contains the following variables:
  • message_text
    is the message text.
  • rc
    is the return code produced when the command executed.
  • reason
    is the reason code produced when the command executed.
  • logrba
    is the relative byte address of the event command in the log.
Processing continues. Commands that contain errors are not completed.
If the command did not execute correctly, correct the error in the command that is indicated by the return and reason codes, or by a reference to another message. Then, submit the command again. For more information on the return and reason codes, see Reason Codes 01440600 to 060906FF PowerExchange Utilities and Reason Codes 00000601 to 00004499 Command.