Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177554 I

PWXEDM
177554
I

Assuming capture directory configuration supports DB2 V
nn
mode
.
The DB2 for z/OS ECCR could not validate the PowerExchange capture directory (TCAP) tables against the reported DB2 version and mode that you use. The ECCR assumes that the capture directory tables are supported even though they might be at a lower DB2 level than the reported DB2 version and mode. In the message text,
nn
is the DB2 version, and
mode
is one of the following values: CM for conversion mode, ENFM for enabling new-function mode, and NFM for new-function mode.
DB2 ECCR processing continues.
No response is required.

0 COMMENTS

We’d like to hear from you!