Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

DTL 0022 E

DTL
0022
E

A PowerExchange Journal exit program library must be specified.
In a CRTPWXENV command, the EXTPGMLIB parameter was set to *NONE, which is an invalid value if a PowerExchange Condense library name is specified in the CONDLIB parameter and the PowerExchange environment is being created in an independent auxiliary storage pool (IASP).
CRTPWXENV command processing ends.
Perform the following actions:
  1. If you want to display additional information for the message, press F1 in the message text on the console.
  2. In the CRTPWXENV command, specify a PowerExchange Journal exit program name in the EXTPGMLIB parameter.
  3. Run the command again.