Message Reference Volume 3

PWXEDM 172650 E

PWXEDM
172650
E

EDM Logger Offload terminated for dsname=
dsname
, reason code=
reason
The PowerExchange Logger off‑load handler was unable to archive active log data set,
dsname
. The reason code,
reason
, indicates the cause of the termination as follows.
  • 01. The PowerExchange Logger was unable to allocate the active log data set.
  • 02. The PowerExchange Logger was unable to identify the active log data set using the DIV IDENTIFY macro.
  • 03. The PowerExchange Logger was unable to access the active log data set using the DIV ACCESS macro.
  • 04. The PowerExchange Logger was unable to map the active log data set using the DIV MAP macro.
  • 05. An I/O error occurred while the PowerExchange Logger was reading the active log data set.
  • 06. An I/O error occurred while the PowerExchange Logger was writing to the active log data set.
The PowerExchange Logger ends the off‑load process.
To determine the cause of the problem, view the JES2 log for previous messages from the PowerExchange physical logger. If the problem persists, contact Informatica Global Customer Support and provide the job step listing.