PWXEDM 177555 E

PWXEDM
177555
E

Capture directory does not support DB2 V
nn
mode
.
During initialization, the DB2 for z/OS ECCR examines the PowerExchange capture directory tables to determine if they support the DB2 version and mode that you use. The ECCR determined that the capture directory tables do not support the specified DB2 version and mode. In the message text,
nn
is the DB2 version, and
mode
is one of the following values: CM for conversion mode, ENFM for enabling new-function mode, and NFM for new-function mode.
The DB2 ECCR ends abnormally.
Run the appropriate jobs from installation that upgrade the capture directory tables. For more information, see the
PowerExchange CDC Guide for z/OS
or
PowerExchange Installation and Upgrade Guide
.