PWXEDM 176402 E

PWXEDM
176402
E

CICS Shutdown (Immediate) requested due to Initialization error/s
During CICS/VSAM ECCR initialization, one or more fatal errors occurred. To prevent change data loss, the CICS region must be shut down.
PowerExchange issues a request to shut down CICS.
To determine the cause of the errors, examine the CICS job log, MVS SYSLOG data set, and PowerExchange message log. Then correct the problem and start the CICS/VSAM ECCR again.