Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172631 E

PWXEDM
172631
E

Specified DSNAME already exists in ERDS, DDNAME=
ddname
You entered a DEFINE_LOG command with a data set name that already exists in the restart data set (ERDS). An entry is made in a restart data set (ERDS) if the specified data set name currently exists in either the active or archive record of that restart data set. The variable
ddname
specifies the DD name of the specified restart data set. The DEFINE_LOG command ends.
Either correct the data set name in the control statement and run the command again, or delete the existing data set name from the restart data set and run the job again.