PWXEDM 177398 E

PWXEDM
177398
E

TABLE '
creator
.
table_name
' PROBABLY NOT DEFINED WITH "DATA CAPTURE CHANGES"
The specified DB2 table might not have been defined with the DATA CAPTURE CHANGES attribute. The DB2 ECCR requires this attribute for change data capture.
See the associated messages to determine how the DB2 ECCR responds.
If the table was not defined with the DATA CAPTURE CHANGES attribute, use an ALTER TABLE statement to specify the DATA CAPTURE CHANGES attribute on the table. Afterwards, the ECCR continues to issue this message each time it starts or gets a refresh request, until it encounters the first change record for the table.