While processing DB2 log records, the DB2 ECCR detected that a log record was not paired with a continuation record. This error can occur in the following situations:
The DB2 ECCR just completed a cold start.
The DB2 ECCR just completed a warm start or refresh process under the following conditions:
New capture registrations were added.
The source tables were altered while the next log records to be processed were being written to the log.
The DB2 ECCR just completed a special start.
The DB2 ECCR discards the unpaired log record. See message PWXEDM177030E to determine whether the DB2 ECCR abends or tries to continue.
If this message is issued occasionally, when one of the situations described in the explanation exist, ignore this error. However, if the message is issued frequently, or for reasons other than those previously described, collect the complete DB2 ECCR job listing, including the SYSUDUMP output, and then contact Informatica Global Customer Support.