The PowerExchange physical logger received an invalid return code from the specified internal MVS data in virtual (DIV) macro for the service indicated. The reason code indicates why the DIV macro processing failed or cannot continue. The task ends abnormally with the user abend code of U3035 and reason code X'F9FF00xx'.
Identify the z/OS data in the virtual (DIV) macro that is causing the problem using the MVS system messages and codes. If necessary, correct the problem, and run the job again.