Message Reference Volume 3

PWXEDM 177373 W

PWXEDM
177373
W

Table '
creator
.
table_name
' DB2 catalog definition not available at ECCR startup
When the DB2 ECCR started, it tried to get a description of the specified table from the DB2 catalog. However, a table description was not available. As a result, the ECCR cannot capture change data for this table. This situation can occur during warm start or refresh processing when a new capture registration is being processed for a table that was created, or dropped and re-created, after the point in the log that the ECCR is processing for the warm start or refresh process.
The DB2 ECCR abends.
Delete the capture registration and warm start the DB2 ECCR. After the ECCR processes past the point in the log where the table was first created or re-created, you can redefine the capture registration and refresh the ECCR .