PWXEDM 172735 E

PWXEDM
172735
E

EDM Logger command processor was expecting a subcommand, found
characters
followed by “=”
The PowerExchange Logger expected to find a subcommand. Instead, it found the specified characters, which are the next characters in the input stream, followed by an equal sign. These characters do not specify a subcommand. Possible reasons for this are:
  • A comma missing between two keywords
  • A level 2 command followed by an equal sign
  • A misspelled subcommand
The PowerExchange Logger ends processing of the current command set.
Correct this command set, and submit it again.