Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172816 E

PWXEDM
172816
E

EDM Logger (
loggerid
) terminated abnormally while an ECCR was active
While an environmental change capture routine (ECCR) was active, the change interface component (CIC) received notice through the Cross‑System Coupling Facility (XCF) that the PowerExchange Logger terminated.
Depending on the value of the system global parameter, CCERR, one of the following actions occur:
The job continues but PowerExchange Change stops. You will lose any changes in progress. (CCERR=CONT)
Processing ends. (CCERR=ABEND)
Determine what caused the PowerExchange Logger to terminate, correct the problem, and restart the PowerExchange Logger.