Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177674E

PWXEDM
177674
E

UNEXPECTED QW0306RS AT
rba_or_lrsn
.
data_sharing_member_id
RC=
return_code
RS=
reason_code
DG=
diagnostic_code
The DB2 ECCR encountered an IF306 error when reading a log record at the specified location.
The DB2 ECCR ends.
Collect the following diagnostic information:
  • SYSUDUMP, SYSABEND, or SYSMDUMP output from the job.
  • Print output from the DB2 DSN1LOGP utility for the log record.
To determine if the error is transient, try to warm start the ECCR. If the restart fails, contact Informatica Global Customer Support. Provide Support with the diagnostic information that you collected.