During initialization, the DB2 for z/OS ECCR examines the PowerExchange capture directory tables to determine if they support the DB2 version and mode that you use. The ECCR found that the specified table contains a column with incorrect column attributes. In the message text,
TCAP_table_name
is the name of the capture directory table, and
column_name
is the name of the column with the incorrect attributes.
The DB2 ECCR continues processing or ends abnormally, depending on the DB2 version.
Check the subsequent PWXEDM177552I message to determine the latest DB2 version that the capture directory tables support. If the tables do not support the version with which the ECCR is running, upgrade the capture directory table to support that DB2 version or a later DB2 version that PowerExchange supports.