PWXEDM176449I

PWXEDM
176449
I

EDMKOVRD Close Error on Override dataset:
data_set_name
(
member
) RC=(
return_code
)
An I/O error occurred when the PowerExchange CICS/VSAM ECCR was processing the specified override options data set in the target CICS Transaction Server (TS) region. An attempt to close the data set resulted in an error.
CICS TS continues running.
Check if the specified data set is accessible and readable in the Time Sharing Option (TSO) environment. If it is not accessible and readable, correct or redefine the data set. If the problem persists, contact Informatica Global Customer Support.