Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177566 W

PWXEDM
177566
W

No prior {Begin Phase2|Phase 1/2 Tran} for End Phase 2 for
urid
.
data_sharing_member_id
at
log_rba_or_lrsn
.
data_sharing_member_id
.
sequence_number
When processing a UR record of type End Phase 2 for a UOW, the DB2 ECCR detected that it had not received the proper sequence of UR records. This situation might mean that an intermediate UR record, such as a Begin Phase2 or Phase 1/2 Tran record, has not been encountered. This message includes the URID for the potentially incorrect UOW and the log location of the beginning of this UOW.
In the message text:
  • "Begin Phase2" or "Phase 1/2 Tran" is the operation or record type that was expected but not encountered prior to the current record for this URID.
  • "End Phase2" is the current record type.
  • urid
    .
    data_sharing_member_id
    is the DB2-assigned URID. In a data-sharing environment, the member ID is included.
  • log_rba_or_lrsn
    .
    data_sharing_member_id
    .
    sequence_number
    is the current log location where the Begin UR for this URID was encountered. In a data-sharing environment, the log LRSN and data-sharing member ID is reported.
Message PWXEDM177565W reports the last log record type that was encountered for this UOW, along with the current DB2 log location at which this problem was encountered.
Processing continues. Because the End Phase2 record was found for this UOW, the UOW is captured correctly and available for further processing. However, because some of the expected UR records were not available, some data records might not have been captured.
Collect the following types of diagnostic information:
  • An SVC dump for the DB2 ECCR and any started tasks for the DB2 subsystem or for data-sharing group members.
  • JES output from the DB2 ECCR and the DB2 subsystem.
  • Output from DB2 DSN1LOGP utility.
  • Copies of the archive logs that contain the log data where this problem was encountered.
Then contact Informatica Global Customer Support.