PWXEDM 177360 E

PWXEDM
177360
E

CAPTURE PROGRAM ABENDS AFTER MULTIPLE RETRIES
The DB2 ECCR accessed the DB2 catalog to get descriptions of the source tables. However, the descriptions were inconsistent, probably because DDL changes were occurring on the tables at the same time as the ECCR was accessing the catalog. The ECCR tried several more times to get consistent table descriptions. Because these attempts were also unsuccessful, the ECCR abends.
The DB2 ECCR abends.
Restart the DB2 ECCR when less DDL activity is occurring. If this action does not correct the problem, collect the complete DB2 ECCR job listing, including the SYSUDUMP output. Then contact Informatica Global Customer Support.