This message is issued when the PowerExchange Logger has received a SIGNON command but there is an error in the command. As a result, the PowerExchange Logger was unable to properly process the SIGNON command.
The name of the PowerExchange Logger (
logger_id
), the name of the process that sent the command (
xcf_member_name
) and the job name under which the sender is executing (
job_name
) are all included in the text of the message.
The message text also includes a description of what problem the PowerExchange Logger found in the SIGNON message. The
reason_text
is one of the following values:
Command received was not request
Command received was not reply
Sender not Post‑Log Merge task
Processing continues. However, if the PowerExchange Logger is waiting for confirmation of a successful signon to the Post‑Log Merge task, the PowerExchange Logger might be unable to complete its initialization process.
Investigate the reason for the error in processing the SIGNON message by the PowerExchange Logger. You may need to refer to messages that may have been issued by the corresponding Post‑Log Merge task for further information on what happened to cause the error in the signon request. If the PowerExchange Logger is currently initializing, and does not complete that process due to the problem described in this message, it may be necessary to recycle either the Post‑Log Merge task or the PowerExchange Logger. If you cannot identify and correct the problem, contact Informatica Global Customer Support.