PWXEDM 176425 W

PWXEDM
176425
W

Registered File(
file_name
) allows read-only access - Change Capture bypassed
The specified VSAM file is registered for change data capture but was opened in read-only mode. Because no changes can be written to a read-only file, PowerExchange does not capture changes from it.
PowerExchange ignores the file and continues change capture processing.