PWXEDM 172019 E

PWXEDM
172019
E

module
: Another EDM Agent is running with AgentID
agentid
The PowerExchange Agent that is currently initializing detected another PowerExchange Agent already running that has the same
agentid
.
The PowerExchange product stops processing the currently initializing PowerExchange Agent.
Determine which instance of the PowerExchange Agent should be running. If the PowerExchange Agent that should be run is the one that is initializing, use the SHUTDOWN command to terminate the currently running PowerExchange Agent.