Message Reference Volume 3

PWXEDM 177546 E

PWXEDM
177546
E

Directory configuration does not support long names.
During DB2 ECCR initialization or refresh processing, the ECCR received a list of the registered tables of CDC interest. One or more of these tables have creator names, table names, or column names that are longer than the name lengths that the existing ECCR capture directory tables can support. For more information, see previous verification messages for the TCAP capture directory tables.
The ECCR ends without processing any DB2 log data.
Remove the source tables that have the long creator names, table names, or column names from CDC sessions, or expand the capture directory tables to support the longer names. Then restart the ECCR. If the problem persists, contact Informatica Global Customer Support.