PWXEDM 177562 E

PWXEDM
177562
E

IFI READS ERROR. WQALLMOD=
parameter_value
WQALLRBA=
rba
IFCARC1=
return_code
IFCARC2=
reason_code
.
The DB2 ECCR issued an IFCID 306 READS call, but the resulting return code or reason code indicated an error. The WQALLMOD and WQALLRBA parameter values are input to the READS call. This message is also usually preceded by one or more additional ECCR messages that provide more information about the problem.
The DB2 ECCR ends.
To diagnose the problem, look for other messages that were issued when the ECCR abend occurred, including messages for abends in the DB2 subsystem to which the DB2 ECCR connects. Then correct any errors that these messages describe and warm start the ECCR. If the problem persists or cannot be identified, contact Informatica Global Customer Support.