Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172039 I

PWXEDM
172039
I

module
: The following JES2 Initiators must be drained before EDM Agent
agentid
can drain:
A DRAIN command was issued for the specified PowerExchange Agent. However, due to SUBSYS DD affinities with the PowerExchange Agent, certain JES2 initiator tasks are currently registered for PowerExchange Agent services. The PowerExchange Agent cannot drain until all registered tasks have terminated. This message is followed by one or more messages listing those initiators that must be drained to allow all registered tasks to terminate.
The PowerExchange Agent remains in draining status.
Drain the specified initiators with the $PIx JES2 command to enable the PowerExchange Agent to complete draining. After each initiator has been drained, you can restart it.