Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172778 W

PWXEDM
172778
W

EDM Logger discarding duplicate Begin UOW from ECCR
eccrname
for UOW
uowsequencenumber
PowerExchange Logger received a begin_UOW record for which it already received the begin_UOW: a duplicate begin_UOW. The text of the message includes the UOWid assigned by the ECCR, as well as the name of the ECCR that supplied the record. This can occur on restart of any type 1 ECCR, the DB2 ECCR is the only type 1 ECCR, if the previous instance of the ECCR was not shutdown using the QUIESCE command.
The following actions occur:
  1. Warning message PWXEDM172778W is issued.
  2. The PowerExchange Logger ignores the begin_UOW record and processing continues.
Complete the following actions:
  1. Check the JES2 log for previous messages from the EDML Logger. Also examine the ECCR that provided the data for any previous messages.
  2. Have the job step listings available if contacting Product Support.

0 COMMENTS

We’d like to hear from you!