EDM Logger discarding duplicate Begin UOW from ECCR
eccrname
for UOW
uowsequencenumber
PowerExchange Logger received a begin_UOW record for which it already received the begin_UOW: a duplicate begin_UOW. The text of the message includes the UOWid assigned by the ECCR, as well as the name of the ECCR that supplied the record. This can occur on restart of any type 1 ECCR, the DB2 ECCR is the only type 1 ECCR, if the previous instance of the ECCR was not shutdown using the QUIESCE command.
The following actions occur:
Warning message PWXEDM172778W is issued.
The PowerExchange Logger ignores the begin_UOW record and processing continues.
Complete the following actions:
Check the JES2 log for previous messages from the EDML Logger. Also examine the ECCR that provided the data for any previous messages.
Have the job step listings available if contacting Product Support.