PWXEDM 172136 E

PWXEDM
172136
E

Creation of SCOPE=COMMON dataspace failed, check PARMLIB MAXCAD limit
An attempt to create a SCOPE=COMMON dataspace for the PowerExchange Agent using the DSPSERV CREATE operand failed. The return code and reason code are given in the DATA = value portion of the previous message. The specific return code and reason code indicate that the maximum number of SCOPE=COMMON dataspaces may have been reached.
The PowerExchange Agent ends.
To increase the limit, change the MAXCAD value in the IEASYSxx member of SYS1.PARMLIB, and re-IPL. Contact Informatica Global Customer Support.