PWXEDM 172630 E

PWXEDM
172630
E

EDM Logger ERDS active log data set record is full, DDNAME=
ddname
The active log data set is full, and you cannot insert additional entries. The variable
ddname
specifies the DD name of the full restart data set (ERDS). The PowerExchange Logger aborts the DEFINE_LOG command with a return code of 8.
Use the VSAM IDCAMS REPRO command to dump the restart data set. Determine the current status of the restart data set, correct the problem, and run the job again.