This message is issued when the PowerExchange Logger has attempted an operation on an internal queue and the return code from the operation indicated that the operation was not successful.
The PowerExchange Logger was processing a UOW record when the error occurred. The type of operation that was attempted (
oper_name
), the name of the internal queue (
queue_name
), the UOW id assigned to the UOW by the PowerExchange Logger (
uow_id
), the return code (
return_code
), and the reason code (
reason_code
) from the failed operation are all included in the text of the message. The return and reason codes for this message, which are generated in EDMQMGR0, are not currently documented.
The value of
oper_name
is one of the following values:
Add (Phase1)
Add (Phase2)
Delete (UOW)
The value of
queue_name
is one of the following parameters:
GBLXCFQCB
GBLOUQQCB
The PowerExchange Logger ends abnormally.
Investigate the reason for the failure in the queue operation, using appropriate operating system documentation, along with any other messages that may have been issued in conjunction with this problem. If you cannot correct the problem, contact Informatica Global Customer Support.