Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177617E

PWXEDM
177617
E

INVALID TRACE OPTION
option
The DB2 ECCR does not recognize the specified trace option. This message is issued either when the ECCR reads the TRACE statements in the REPL2OPT DD data set at startup or when you enter the MVS F
eccr_job_name
,TR {ACT|INACT},
trace_id
command to start or stop a trace.
If a TRACE statement in the REPL2OPT data set contains an invalid option, the DB2 ECCR abends. If the TR command contains an invalid option, the ECCR ignores the command and continues processing.
In the REPL2OPT TRACE statement or the TR command, enter a valid option. For information about valid TRACE options, see the
PowerExchange CDC Guide for z/OS
. Alternatively, for the TR command, enter either the ACT or INACT option. For information about the TR command, see the
PowerExchange Command Reference
.

0 COMMENTS