PWXEDM 172847 W

PWXEDM
172847
W

Following unit of work requires manual resolution, SUBSYSTEM=
sub_system
TOKEN=
UOWID
.
This message indicates that the UOW identified by the sub_system and UOWID variables is in doubt and requires intervention to resolve.
Processing continues.
You must manually resolve the UOW in question. If IMS is in doubt, issue the IMS /CHANGE command, with the CCTL and PRTKN options to resolve the UOW. For more information about this command, see the IBM IMS documentation. If IMS is not in doubt, issue the PowerExchange Logger RESOLVE_INDOUBT command to resolve the UOW. For more information about this command, see the