Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 177537 E

PWXEDM
177537
E

Excessive {column name|old column name|new column name} length (
length
) found in table '
creator
.
table_name
'. Truncated {column name|old column name|new column name}:
column_name
When processing log records for the DB2 catalog, the DB2 ECCR encountered a column name that is longer than the maximum length that the ECCR supports. The ECCR cannot properly record the definition of the table in its tracking table because of the excessive column length. This message includes the length of the column name that is too long, the name of the registered table that includes the column, and the column name.
The message reports the
column name
length when the table is added to the capture interest list during an ECCR warm start or refresh process. The message reports the
old column name
or
new column name
lengths when the ECCR processes DB2 log records for column rename operations.
The DB2 ECCR ends.
The DB2 ECCR does not support capturing changes from the table because the column length in the catalog is too long. Remove the table from capture processing and then warm start the DB2 ECCR. If the problem occurs again, contact Informatica Global Customer Support.

0 COMMENTS

We’d like to hear from you!