Table of Contents

Search

  1. Preface
  2. DTL0001 to DTL3004
  3. DTL58001 to DTL62591
  4. PWXEDM172000 to PWXEDM173002
  5. PWXEDM175000 to PWXEDM175648
  6. PWXEDM176400 to PWXEDM177699
  7. PWXEDM181200 to PWXEDM181599
  8. PWXEDM261000 to PWXEDM263999
  9. Abend, Return, and Reason Codes in PowerExchange Messages

Message Reference Volume 3

Message Reference Volume 3

PWXEDM 172679 I

PWXEDM
172679
I

EDP Logger
report_title
report follows:
The PowerExchange Logger for MVS DISPLAY OBJECT=LOG and DISPLAY OBJECT=CONNECTION commands generate this message to show the title of the report that the commands generate. This message precedes other messages in the report. The
report_title
value can be any of the following values:
  • Log_Active
  • Log_Archive
  • UOW_Connection
  • Reader_Connection
  • Writer_Connection
Additionally, if you enter the DISPLAY OBJECT=CONNECTION ,TYPE=READER command in a Post_Log Merge environment, this message shows includes the following line in the connection reader report:
Log_RBA=
logger_rba
, Read_RBA=
read_rba
, Start_Loc=
start_location
This line appears as an unnumbered message line within the report in PWXEDM172679I. The line reports the following information for the current reader connections:
  • Log_RBA. An RBA that indicates where the PowerExchange Logger is currently writing data.
  • Read_RBA. An RBA that indicates where the log reader last processed.
  • Start_Loc. A time stamp that indicates where the read request started. This timestamp is in TOD clock format.
The Log_RBA and Read_RBA indicate the beginning of a block of Logger data. They do not reflect the record that is currently being processed within that block.
Processing continues.
No response is required.

0 COMMENTS

We’d like to hear from you!