PWXEDM 172554 E

PWXEDM
172554
E

Logger
logger_id
attempting to write to active log
dataset_name
at RBA
rba
, but is quiesced
This message is issued when the PowerExchange Logger has attempted to log some data but the Physical Logger has determined that the PowerExchange Logger is quiesced. When a PowerExchange Logger is quiesced, it must not write any new data to the current active log data set because the Post‑Log Merge task will not retrieve it.
The name of the PowerExchange Logger that encountered this problem (
logger_id
), the name of the active log data set it was attempting to write to (
dataset_name
), and the RBA location that was to be written (
rba
) are all included in the text of the message.
The PowerExchange Logger ends abnormally.
This situation indicates that a logic error has occurred in the processing of a PowerExchange Logger that is quiesced. PowerExchange Loggers only become quiesced in a Post‑Log Merge environment. You need to gather the output from the PowerExchange Logger and its corresponding PowerExchange Agent, and report the problem to Informatica Global Customer Support.