The DB2 ECCR successfully issued an IFCID READS call but the QW0306CT count of data records in the returned log data was zero. This situation indicates a logical error in the DB2‑supplied IFCID 306 interface.
The DB2 ECCR ends.
To diagnose the problem, look for other messages that might have been issued when the ECCR abend occurred, including messages for abends in the DB2 subsystem to which the DB2 ECCR connects. Then correct any errors that these messages describe and warm start the ECCR. If the problem persists or cannot be identified, contact Informatica Global Customer Support.