PWX- 09890

PWX-
09890

Datacom Multi User Facility is not active for Change Data Capture
function
, Reply Y to continue or N to cancel.
The Datacom MUF is not active for one of the following Datacom table-based CDC functions:
  • ECCR. The ECCR might have been started when the MUF was not running.
  • Cleanup. The MUF has probably crashed or been inadvertently shutdown by the operator.
The ECCR waits for a user response.
Your response depends on whether the MUF is not active for ECCR or cleanup:
  • ECCR. Restart the MUF and then respond Y to the message.
  • Cleanup. Stop the ECCR and restart it.