PWX- 06810

PWX-
06810

DB2 for i5/OS CDC cannot generate missing NR entry from PR entry
receiver_object
.
PowerExchange attempted to generate a next receiver (NR) journal entry based on the previous receiver (PR) entry because
i5/OS
did not supply an NR entry and the ALWNONRENT=Y parameter is specified in the AS4J CAPI_CONNECTION statement. PowerExchange CDC for DB2 for
i5/OS
requires an NR entry to continue processing to the next receiver in the chain when the current journal receiver becomes full. However, the generation of the NR entry failed because PowerExchange was unable to determine the value to use.
Capture processing ends.
The previous receiver in the current chain might have been deleted from the system. If the previous receiver was deleted, either restore the receiver and run the extraction again or restart the extraction from a later restart point. If the previous receiver was not deleted, contact Informatica Global Customer Support.